DECKFRAME deck framing is made entirely from steel which means it is termite proof and is the ideal solution for any termite and insect prone areas where timber is a concern. Furthermore DECKFRAME deck framing is non-combustible with 0 indices for flame-spread, flammability, ignigtability and smoke development so is

Keep fire from gaining a foothold on your deck or inside your home's walls with these flame-resistant framing materials. timberwood material for fireproof deck decay and termite infestation, FRX fire-retardant lumber holds a Class A rating, and is an affordable alternative to other noncombustible framing materials. FRX is

Metal, concrete or brick. Decking and stair treads. Enclosed. Bushfire-resisting timber 2. Tiled or concrete decks. Open. Balustrades and Handrails. Enclosed. Less than 125 mm from any glazing or any combustible wall handrails and balustrades shall made from non combustible material or bushfire-resisting timber 2.

a bushfire-resisting timber or. a timber species from E1 or. made from a non-combustible material or. fibre cement at least 6 mm thick or. any combination of the above materials. Decking with enclosed or unenclosed sub-floor. Decking more than 300 mm. Use timber as usual, e g treated pine from a glazed element.

Avoid flammable shrubs like eucalypts and media like woodchips as these just become fuel for a fire; Keep your verandah well maintained by sealing timber with a non-combustible seal. Fill in small gaps around the deck structure where an ember might be able to lodge - larger openings can be fitted with ember guards

No special requirements for framing or supports. Decking to be non-combustible or bushfire resistant within 300mm horizontally and 400mm vertically from a glazed element. BAL-19 BAL-29, Enclosed sub-floor space or non-combustible or bushfire-resistant timber supports. Decking must be non-combustible. BAL-40

decks shall be a minimum of 1-hour fire-resistance-rated construction, heavy timber construction, or constructed of approved noncombustible materials or fire-retardant-treated wood identified for exterior use and meeting the requirements of Section 2303.2 of the International Building Code. When … any

A fibre cement decking solution that does not rot, crack, warp, is resistant to termites and fire. Attractive Bushfire approved (BAL-FZ) HardieDeck boards are deemed non-combustible by the National Construction Code (NCC) of Australia. HardieDeck is HardieDeck can be installed in up to half the time of a timber deck.

Enclose the space below the deck using mesh or bushfire resistant timbers. Utilise fire retardant decking materials. Seal the timber with a non-combustible seal. Avoid using flammable shrubs or wood chips for landscaping along the deck's edge. Use instead decorative stones or more fire resistant plants.